Datasheet
Section 15 Serial Communication Interface (SCI, IrDA) 
Page 924 of 1384    R01UH0310EJ0500 Rev. 5.00 
 Sep 25, 2012 
H8S/2426, H8S/2426R, H8S/2424 Group
Yes
<End>
[1]
No
Initialization
Start of reception
[2]
No
Yes
Read RDRF flag in SSR [4]
[5]
Clear RE bit in SCR to 0
Error processing
(Continued below)
[3]
Read receive data in RDR, and
clear RDRF flag in SSR to 0
No
Yes
ORER = 1?
RDRF = 1?
All data received?
Read ORER flag in SSR
[1]
[2] [3] 
[4]
[5] 
 SCI initialization:
The RxD pin is automatically 
designated as the receive data 
input pin.
 Receive error handling:
If a receive error occurs, read the 
ORER flag in SSR, and after 
performing the appropriate error 
handling, clear the ORER flag to 
0. Transfer cannot be resumed if 
the ORER flag is set to 1. 
SCI status check and receive 
data read:
Read SSR and check that the 
RDRF flag is set to 1, then read 
the receive data in RDR and 
clear the RDRF flag to 0. 
Transition of the RDRF flag from 
0 to 1 can also be identified by 
an RXI interrupt.
Serial reception continuation 
procedure:
To continue serial reception, 
before the MSB (bit 7) of the 
current frame is received, finish 
reading the RDRF flag, reading 
RDR, and clearing the RDRF flag 
to 0. The RDRF flag is cleared 
automatically when the DMAC or 
DTC is activated by a receive- 
data-full interrupt (RXI) request 
and the RDR value is read.
<End>
Error handling 
Overrun error handling
[3]
Clear ORER flag in SSR to 0
Figure 15.19 Sample Serial Reception Flowchart 