12.4.8  Pulse Output Triggered by Input Capture 
Pulse output can be triggered by TPU input capture as well as by compare match. If TGRA 
functions as an input capture register in the TPU channel selected by PCR, pulse output will be 
triggered by the input capture signal. 
Figure 12.11 shows the timing of this output. 
N
MN
TIOC pin
φ
Input capture
signal
NDR
PODR
MN
PO