Datasheet
Section 11 16-Bit Timer Pulse Unit (TPU) 
R01UH0310EJ0500 Rev. 5.00    Page 751 of 1384 
Sep 25, 2012     
H8S/2426, H8S/2426R, H8S/2424 Group 
(b)  Free-running count operation and periodic count operation 
Immediately after a reset, the TPU's TCNT counters are all designated as free-running 
counters. When the relevant bit in TSTR is set to 1 the corresponding TCNT counter starts up-
count operation as a free-running counter. When TCNT overflows (changes from H'FFFF to 
H'0000), the TCFV bit in TSR is set to 1. If the value of the corresponding TCIEV bit in TIER 
is 1 at this point, the TPU requests an interrupt. After overflow, TCNT starts counting up again 
from H'0000. 
Figure 11.4 illustrates free-running counter operation. 
TCNT value
H'FFFF
H'0000
CST bit
TCFV
Time
Figure 11.4 Free-Running Counter Operation 
When compare match is selected as the TCNT clearing source, the TCNT counter for the 
relevant channel performs periodic count operation. The TGR register for setting the period is 
designated as an output compare register, and counter clearing by compare match is selected 
by means of bits CCLR2 to CCLR0 in TCR. After the settings have been made, TCNT starts 
count-up operation as a periodic counter when the corresponding bit in TSTR is set to 1. When 
the count value matches the value in TGR, the TGF bit in TSR is set to 1 and TCNT is cleared 
to H'0000. 
If the value of the corresponding TGIE bit in TIER is 1 at this point, the TPU requests an 
interrupt. After a compare match, TCNT starts counting up again from H'0000. 