Datasheet
Section 11 16-Bit Timer Pulse Unit (TPU) 
R01UH0310EJ0500 Rev. 5.00    Page 749 of 1384 
Sep 25, 2012     
H8S/2426, H8S/2426R, H8S/2424 Group 
11.4  Operation 
11.4.1  Basic Functions 
Each channel has a TCNT and TGR register. TCNT performs up-counting, and is also capable of 
free-running operation, periodic counting, and external event counting. 
Each TGR can be used as an input capture register or output compare register. 
(1)  Counter Operation 
When one of bits CST0 to CST5 is set to 1 in TSTR, the TCNT counter for the corresponding 
channel starts counting. TCNT can operate as a free-running counter, periodic counter, and so on. 
(a)  Example of count operation setting procedure 
Figure 11.3 shows an example of the count operation setting procedure. 