Datasheet
Section 11 16-Bit Timer Pulse Unit (TPU) 
R01UH0310EJ0500 Rev. 5.00    Page 747 of 1384 
Sep 25, 2012     
H8S/2426, H8S/2426R, H8S/2424 Group 
11.3.10  Timer Start Register B (TSTRB) 
TSTRB selects operation/stoppage for channels 6 to 11. When setting the operating mode in 
TMDR or setting the count clock in TCR, first stop the TCNT counter. 
Bit  Bit Name  Initial value  R/W  Description 
7 
6 
⎯ 
⎯ 
0 
0 
⎯ 
⎯ 
Reserved 
The write value should always be 0. 
5 
4 
3 
2 
1 
0 
CST11 
CST10 
CST9 
CST8 
CST7 
CST6 
0 
0 
0 
0 
0 
0 
R/W 
R/W 
R/W 
R/W 
R/W 
R/W 
Counter Start 11 to 6 
These bits select operation or stoppage for TCNT. 
If 0 is written to the CST bit during operation with the 
TIOC pin designated for output, the counter stops 
but the TIOC pin output compare output level is 
retained. If TIOR is written to when the CST bit is 
cleared to 0, the pin output level will be changed to 
the set initial output value. 
0: TCNT_11 to TCNT_6 count operation is stopped 
1: TCNT_11 to TCNT_6 performs count operation 