Datasheet
Section 25 Electrical Characteristics 
Page 1304 of 1384    R01UH0310EJ0500 Rev. 5.00 
 Sep 25, 2012 
H8S/2426, H8S/2426R, H8S/2424 Group
(3)  Bus Timing 
Table 25.45  Bus Timing (1) 
Conditions: V
CC
 = 4.5 V to 5.5 V, AV
CC
 = 4.5 V to 5.5 V, V
ref
 = 4.5 V to AV
CC
, V
SS
 = AV
SS
 = 0 V, 
φ = 8 MHz to 33 MHz 
Item Symbol Min. Max. Unit Test Conditions 
Address delay time  t
AD
  ⎯ 20 ns 
Address setup time 1  t
AS1
 0.5 × t
cyc
 −13  ⎯ ns 
Address setup time 2  t
AS2
 1.0 × t
cyc
 −13  ⎯ ns 
Address setup time 3  t
AS3
 1.5 × t
cyc
 −13  ⎯ ns 
Address setup time 4  t
AS4
 2.0 × t
cyc
 −13  ⎯ ns 
Figures 25.58 to 
25.68 
Address hold time 1  t
AH1
 0.5 × t
cyc
 −8  ⎯ ns  
Address hold time 2  t
AH2
 1.0 × t
cyc
 −8  ⎯ ns  
Address hold time 3  t
AH3
 1.5 × t
cyc
 −8  ⎯ ns  
CS delay time 1  t
CSD1
  ⎯ 15 ns  
AS delay time  t
ASD
  ⎯ 15 ns  
RD delay time 1  t
RSD1
  ⎯ 15 ns  
RD delay time 2  t
RSD2
  ⎯ 15 ns  
Read data setup time 1  t
RDS1
 15  ⎯ ns  
Read data setup time 2  t
RDS2
 15  ⎯ ns  
Read data hold time 1  t
RDH1
 0  ⎯ ns  
Read data hold time 2  t
RDH2
 0  ⎯ ns  
Read data access time 2  t
AC2
  ⎯ 1.5 × t
cyc
 − 25  ns   
Read data access time 4  t
AC4
  ⎯ 2.5 × t
cyc
 − 25  ns   
Read data access time 5  t
AC5
  ⎯ 1.0 × t
cyc
 − 25  ns   
Counter address read data access time 1  t
AA1
  ⎯ 1.0 × t
cyc
 − 25  ns 
Counter address read data access time 2  t
AA2
  ⎯ 1.5 × t
cyc
 − 25  ns 
Counter address read data access time 3  t
AA3
  ⎯ 2.0 × t
cyc
 − 25  ns   
Counter address read data access time 4  t
AA4
  ⎯ 2.5 × t
cyc
 − 25  ns   
Counter address read data access time 5  t
AA5
  ⎯ 3.0 × t
cyc
 − 25  ns   
Counter address read data access time 6  t
AA6
  ⎯ 4.0 × t
cyc
 − 25  ns   
Multiplexed address delay time  t
MAD
  ⎯ 20 ns 
Multiplexed address setup time 1  t
MAS1
 0.5 × t
cyc
 − 15  ⎯ ns 
Multiplexed address setup time 2  t
MAS2
 1.5 × t
cyc
 − 15  ⎯ ns 
Multiplexed address hold time  t
MAH
 1.0 × t
cyc
 − 15  ⎯ ns 
AH delay time  t
AHD
  ⎯ 15 ns 