Datasheet
Section 21 Flash Memory 
Page 1120 of 1384    R01UH0310EJ0500 Rev. 5.00 
 Sep 25, 2012 
H8S/2426, H8S/2426R, H8S/2424 Group
Where the sequence of programming operations that is executed includes programming with 
another method or of another ROM, the procedure must be repeated from the programming 
selection command. 
The sequence for programming-selection and 128-byte programming commands is shown in 
figure 21.12. 
Transfer of the 
programming 
program
Host Boot program
Programming selection (H'42, H'43, H'44)
ACK
Programming
128-byte programming (address, data)
ACK
128-byte programming (H'FFFFFFFF)
ACK
Repeat
Figure 21.12 Programming Sequence 
(a)  User-Program Programming Selection 
The boot program will transfer a program for programming. The data is programmed to the user 
ROMs by the transferred program for programming. 
Command H'43 
•  Command, H'43, (1 byte): User-program programming selection 
Response H'06 
•  Response, H'06, (1 byte): Response to user-program programming selection 
When the programming program has been transferred, the boot program will return ACK. 
Error response  H'C3  ERROR 
•  Error response, H'C3, (1 byte): Error response for user-program programming selection 
•  ERROR: (1 byte): Error code 
H'54:  Selection processing error (transfer error occurs and processing is not completed) 