Datasheet
Section 19 Synchronous Serial Communication Unit (SSU) 
R01UH0310EJ0500 Rev. 5.00    Page 1063 of 1384 
Sep 25, 2012     
H8S/2426, H8S/2426R, H8S/2424 Group 
Yes
[1]
[2]
[3]
[4]
[5]
[6]
[1] Initial setting:
  Specify the receive data format.
[2] Start reception: 
  When SSRDR is dummy-read with RE = 1, reception is 
 started.
[3], [6] Receive error processing: 
  When a receive error occurs, execute the designated error 
  processing after reading the ORER bit in SSSR. After that, 
  clear the ORER bit to 0. While the ORER bit is set to 1, 
  transmission or reception is not resumed.
[4]  To continue single reception:
  When continuing single reception, wait for time of t
SUcyc
  while the RDRF flag is set to 1 and then read receive data
 in SSRDR.
  The next single reception starts after reading receive data 
 in SSRDR.
[5]  To complete reception:
  To complete reception, read receive data after clearing the 
  RE bit to 0. When reading SSRDR without clearing the RE 
  bit, reception is resumed. 
No
Yes
Yes
No
Start
Initial setting
Dummy-read SSRDR
Read SSSR
RDRF = 1?
ORER = 1?
Consecutive data 
reception?
Read received data in SSRDR
RDRF automatically cleared
RE = 0
Read receive data in SSRDR
End reception
Overrun error processing
Clear ORER in SSSR
End reception
Note: Hatching boxes represent SSU internal operations.
No
Figure 19.8 Flowchart Example of Data Reception (SSU Mode) 