Datasheet
Section 19 Synchronous Serial Communication Unit (SSU) 
R01UH0310EJ0500 Rev. 5.00    Page 1059 of 1384 
Sep 25, 2012     
H8S/2426, H8S/2426R, H8S/2424 Group 
Yes
Start
[1]
[2]
[3]
[1] Initial setting:
  Specify the transmit data format.
[2] Check that the SSU state and write transmit data:
  Write transmit data to SSTDR after reading and confirming 
  that the TDRE bit is 1. The TDRE bit is automatically cleared 
  to 0 and transmission is started by writing data to SSTDR. 
[3] Procedure for consecutive data transmission:
 To continue data transmission, confirm that the TDRE bit is 1
  meaning that SSTDR is ready to be written to. After that, data
  can be written to SSTDR. The TDRE bit is automatically 
  cleared to 0 by writing data to SSTDR.
[4] Procedure for data transmission end:
  To end data transmission, confirm that the TEND bit is cleared 
  to 0. After completion of transmitting the last bit, clear the TE 
  bit to 0.
Note: Hatching boxes represent SSU internal operations.
Initial setting
Read TDRE in SSSR
TDRE = 1?
Yes
Yes
No
No
No
Write transmit data to SSTDR
TDRE automatically cleared
Data transferred from SSTDR to SSTRSR
Set TDRE to 1 to start transmission
Consecutive data transmission?
Read TEND in SSSR
TEND = 1?
Clear TEND to 0
Clear TE in SSER to 0
End transmission
Yes
No
Confirm that TEND is cleared to 0
One bit time 
quantum elapsed?
[4]
Figure 19.6 Flowchart Example of Data Transmission (SSU Mode) 