Datasheet
Section 2 CPU 
Page 74 of 1384    R01UH0310EJ0500 Rev. 5.00 
 Sep 25, 2012 
H8S/2426, H8S/2426R, H8S/2424 Group
2.7  Addressing Modes and Effective Address Calculation 
The H8S/2600 CPU supports the eight addressing modes listed in table 2.11. The usable address 
modes are different in each instruction. 
Arithmetic and logic instructions can use the register direct and immediate modes. Data transfer 
instructions can use all addressing modes except program-counter relative and memory indirect. 
Bit manipulation instructions use register direct, register indirect, or absolute addressing mode to 
specify an operand, and register direct (BSET, BCLR, BNOT, and BTST instructions) or 
immediate (3-bit) addressing mode to specify a bit number in the operand. 
Table 2.11  Addressing Modes 
No. Addressing Mode  Symbol 
1 Register direct  Rn 
2 Register indirect  @ERn 
3  Register indirect with displacement @(d:16,ERn)/@(d:32,ERn) 
4  Register indirect with post-increment 
Register indirect with pre-decrement 
@ERn+ 
@–ERn 
5 Absolute address  @aa:8/@aa:16/@aa:24/@aa:32 
6 Immediate  #xx:8/#xx:16/#xx:32 
7 Program-counter relative @(d:8,PC)/@(d:16,PC) 
8 Memory indirect  @@aa:8 
2.7.1  Register Direct—Rn 
The register field of the instruction code specifies an 8-, 16-, or 32-bit general register containing 
the operand. R0H to R7H and R0L to R7L can be specified as 8-bit registers. R0 to R7 and E0 to 
E7 can be specified as 16-bit registers. ER0 to ER7 can be specified as 32-bit registers. 
2.7.2  Register Indirect—@ERn 
The register field of the instruction code specifies an address register (ERn) which contains the 
address of the operand on memory. If the address is a program instruction address, the lower 24 
bits are valid and the upper 8 bits are all assumed to be 0 (H'00). 