Datasheet
Section 22 Power-Down Modes
Rev. 3.00 Sep. 28, 2009 Page 637 of 710
REJ09B0384-0300
• MSTPCRA
Bit Bit Name
Initial
Value
R/W Corresponding Module
7 to 3 MSTPA7 to
MSTPA3
All 0 R/W Reserved
The initial values should not be changed.
2 MSTPA2 0 R/W 14-bit PWM timer (PWMX_1)
1 MSTPA1 0 R/W 14-bit PWM timer (PWMX_0)
0 MSTPA0 0 R/W Reserved
The initial value should not be changed.
MSTPCR sets operation and stop by the combination of bits as follows:
MSTPCRH (bit 3)
MSTP11
MSTPCRA (bit 2)
MSTPA2
Function
0 0 14-bit PWM timer (PWMX_1) operates.
0 1 14-bit PWM timer (PWMX_1) stops.
1 x
MSTPCRH (bit 3)
MSTP11
MSTPCRA (bit 1)
MSTPA1
Function
0 0 14-bit PWM timer (PWMX_0) operates.
0 1 14-bit PWM timer (PWMX_0) stops.
1 x
Note: Bit 3 of MSTPCRH is the module stop bit for PWMX_0 and PWMX_1.
[Legend] x: Don't care