The event link function can be used to set the ADST bit. When the event specified in ELSR10
or ELS11 of the ELC occurs, the corresponding ADST bits (in A/D converter unit 1 or A/D
converter unit 2, respectively) are set and the A/D conversion or comparison starts.
To select AN0 and AN0_2 as the channels for conversion, specify analog input operation for
the pins by setting the PMRA2 and PMRA3 bits.
24.2.3 A/D Control Register (ADCR)
Address:
Bit:
Value after reset:
b7
0
b6
0
b5
SCANE
0
b4
SCANS
0
b3
1
b2
0
b1
ADSTCLR
0
b0
EXTRGS
0
H'FF05F1, H'FF0611
TRGS[1:0] CKS[1:0]
Bit Symbol Bit Name Description R/W
7, 6 TRGS[1:0] Trigger select 1
and 0
b0 b7 b6
0 0 0: A/D conversion start by external trigger is
disabled.
0 0 1: A/D conversion start by external trigger pin
1 (ADTRG1) is enabled.
0 1 0: A/D conversion start by external trigger pin
2 (ADTRG2) is enabled.*
1
0 1 1: A/D conversion start by external trigger
(timer RC) is enabled.*
2
1 0 0: A/D conversion start by external trigger
(timer RD_0) is enabled.
1 0 1: A/D conversion start by external trigger
(timer RD_1) is enabled.*
3
1 1 x: Reserved (setting prohibited)
R/W
5 SCANE
4 SCANS
Channel
selection mode
0x: Single mode
10: Scan mode (A/D conversion is performed
continuously for channels 1 to 4)
11: Scan mode (A/D conversion is performed
continuously for channels 1 to 8.)
R/W
3, 2 CKS[1:0]*
4
Clock select 1
to 0
00: Setting prohibited
01: Setting prohibited
10: A/D conversion time = 84 states (max) (initial
value)
11: A/D conversion time = 43 states (max)