Datasheet

Section 20 Serial Communication Interface 3 (SCI3, IrDA)
REJ09B0465-0300 Rev. 3.00 Page 705 of 982
Sep 17, 2010
H8S/20103, H8S/20203, H8S/20223, H8S/20115, H8S/20215, H8S/20235 Group
<End>
(A)
Receive error processing
Parity error processing
Yes
No
Clear OER, PER, and
FER flags in SSR to 0
No
Yes
No
Yes
Framing error processing
No
Yes
Overrun error processing
OER = 1
FER = 1
Break?
PER = 1
[4]
Figure 20.8 Sample Flowchart for Data Reception (Asynchronous Mode) (2)