Datasheet
Section 16 Timer RD
REJ09B0465-0300 Rev. 3.00 Page 553 of 982
Sep 17, 2010
H8S/20103, H8S/20203, H8S/20223, H8S/20115, H8S/20215, H8S/20235 Group
(2) Input Capture Signal Timing
Input capture on the rising edge, falling edge, or both edges can be selected through settings in
TRDIOR. Figure 16.18 shows the timing when the rising edge is selected.
TRDCNT
Input capture signal
Input capture input
GR
N
N
φ
Figure 16.18 Input Capture Signal Timing