Datasheet
Section 15 Timer RC
Page 494 of 982 REJ09B0465-0300 Rev. 3.00
Sep 17, 2010
H8S/20103, H8S/20203, H8S/20223, H8S/20115, H8S/20215, H8S/20235 Group
15.4.9 Timing of A/D Conversion Start Trigger Generation on Compare Match
Figure 15.36 shows the timing of the A/D conversion start trigger generation on compare match.
GR
TRCCNT
TRCCNT input
φ
N
N
N + 1
Compare match
signal
A/D conversion
trigger signal
Figure 15.36 Timing of A/D Conversion Start Trigger Generation on Compare Match