17.2.3  Timer RE Hour Data Register (TREHR) 
Address:
Bit:
Value after reset:
b7
BSY
⎯
b6
⎯
0
b5
HR11
⎯
b4
HR10
⎯
b3
HR03
⎯
b2
HR02
⎯
b1
HR01 
⎯
b0
HR00 
⎯
H'FFFFAA
Bit Symbol Bit Name  Description  R/W 
7  BSY  Timer RE busy  This bit is set to 1 when the timer RE is updating (calculating) 
the values of second, minute, hour, and day-of-week data 
registers. When this bit is 0, the values of second, minute, 
hour, and day-of-week data registers must be adopted. 
R 
6  ⎯  Reserved  This bit is read as 0. The write value should be 0.  ⎯ 
5 HR11  R/W 
4 HR10 
Counting ten's 
position of 
hours 
Counts on 0 to 2 for ten's position of hours 
R/W 
3 HR03  R/W 
2 HR02  R/W 
1 HR01  R/W 
0 HR00 
Counting one's 
position of 
hours 
Counts on 0 to 9 once per hour. When a carry is generated, 1 
is added to the ten's position. 
R/W 
TREHR is used in realtime clock mode and counts the BCD-coded hour value on the carry 
generated once per hour by TREMIN. TREHR is incremented either from decimal 00 to 11 or 00 
to 23 by the selection of the 12/24 bit in TRECR1. This register is not used in output-compare 