Datasheet

Section 14 Timer RB
Page 424 of 982 REJ09B0465-0300 Rev. 3.00
Sep 17, 2010
H8S/20103, H8S/20203, H8S/20223, H8S/20115, H8S/20215, H8S/20235 Group
Bit Symbol Bit Name Description R/W
0 TOPL Timer RB output
level select
Programmable Waveform Generation Mode
0: A high-level signal is output in primary period, a
low-level signal in secondary period and a low-
level signal when the timer stops.
1: A low-level signal is output in primary period, a
high-level signal in secondary period, and a
high-level signal when the timer stops.
Programmable one-shot generation mode
0: A high-level signal is output for one-shot pulse
output and a low-level signal when the timer
stops.
1: A low-level signal is output for one-shot pulse
output and a high-level signal when the timer
stops.
Programmable wait one-shot generation mode
0: A high-level signal is output for one-shot pulse
output and a low-level signal during the wait time
or the time when the timer stops.
1: A low-level signal is output for one-shot pulse
output and a high-level signal during the wait
time or the time when the timer stops.
This bit should be 0 in timer mode.
R/W
INOSEG bit (one-shot trigger polarity select)
Selects an edge for the one-shot trigger signal input from the TRGB pin in programmable one-
shot generation mode or programmable wait one-shot generation mode. This bit should be 0 in
timer mode or programmable waveform generation mode.
INOSTG bit (one-shot trigger control)
Enables or disables one-shot trigger signal input from the TRGB pin. This bit should be 0 in
timer mode or programmable waveform generation mode.
TOCNT bit (timer RB output switch)
For TRBO output state or output change conditions in each mode, see section 14.3.6, TOCNT
Settings and Pin State Update Conditions.
TOPL bit (timer RB output level select)
This bit should be 0 in timer mode.