Datasheet
Section 12 Event Link Controller
REJ09B0465-0300 Rev. 3.00 Page 399 of 982
Sep 17, 2010
H8S/20103, H8S/20203, H8S/20223, H8S/20115, H8S/20215, H8S/20235 Group
φELC/one cycle
φELC/32768 cycles
Channel × selectable frequency
(16 counter cycles)
Event output x
φELC
Latch Latch Latch
ELC timer event n
(n = 0 to 3)
Delay time can be specified using ELTMDR.
C
Q
D
C
Q
D
C
Q
D
ELTMDR
Figure 12.8 Operation of Event-Generation Timer