Datasheet
Section 6 Power-Down Modes
REJ09B0465-0300 Rev. 3.00 Page 145 of 982
Sep 17, 2010
H8S/20103, H8S/20203, H8S/20223, H8S/20115, H8S/20215, H8S/20235 Group
6.1.4 Module Standby Control Register 3 (MSTCR3)
b7
MSTTMRA
1
b6
MSTTMRB
1
b5
MSTTMRC
1
b4
MSTTMRD1
1
b3
MSTTMRD2
1
b2
MSTTMRG
1
b1
⎯
1
b0
MSTTMRE
0
H'FFFFDE
Bit:
Address:
Value after reset:
Bit Symbol Bit Name Description R/W
7 MSTTMRA Timer RA
module standby
0: Operating state
1: Standby state
R/W
6 MSTTMRB Timer RB
module standby
0: Operating state
1: Standby state
R/W
5 MSTTMRC Timer RC
module standby
0: Operating state
1: Standby state
R/W
4 MSTTMRD1 Timer RD unit 0
module standby
0: Operating state
1: Standby state
R/W
3 MSTTMRD2 Timer RD unit 1
module standby
0: Operating state
1: Standby state
R/W
2 MSTTMRG Timer RG
module standby
0: Operating state
1: Standby state
R/W
1 ⎯ Reserved This bit is read as 1. The write value should be 1. ⎯
0 MSTTMRE Timer RE
module standby
0: Operating state
1: Standby state
R/W
Notes: 1. When a peripheral module is in the module standby state, the registers of the module
cannot be accessed.
2. When writing to this register, write 1s to the reserved bits.