Datasheet
R1LP5256E Series
R10DS0070EJ0100 Rev.1.00 Page 5 of
13
2011.04.13
DC Operating Conditions
Parameter Symbol Min. Typ. Max. Unit Note
Vcc 4.5 5.0 5.5 V
Supply voltage
Vss 0 0 0 V
Input high voltage V
IH
2.2 - Vcc+0.3 V
Input low voltage V
IL
-0.3 - 0.8 V 1
R Ver. 0 - +70 °C 2
Ambient temperature range
I Ver.
Ta
-40 - +85 °C 2
Note 1. –3.0V for pulse ≤ 30ns (full width at half maximum)
2. Ambient temperature range depends on R/I-version. Please see table on page 1.
DC Characteristics
Parameter Symbol Min. Typ. Max. Unit Test conditions
Input leakage current | I
LI
| - - 1 μA Vin = Vss to Vcc
Output leakage current
| I
LO
| - - 1 μA
CS# =V
IH
or OE# =V
IH
,
VI/O =Vss to Vcc
I
CC1
- 25 35 mA
Min. cycle, duty =100%, II/O = 0mA
CS# =V
IL
, Others = V
IH
/V
IL
Average operating current
I
CC2
- 2 4 mA
Cycle =1μs, duty =100%, II/O = 0mA
CS# ≤ 0.2V,
V
IH
≥ Vcc-0.2V, V
IL
≤ 0.2V
Standby current
I
SB
- - 3 mA
CS# =V
IH
,
Others = Vss to Vcc
- 1
*1
2 μA ~+25°C
- - 3 μA ~+40°C
- - 8 μA ~+70°C
Standby current
I
SB1
- - 10 μA ~+85°C
Vin = Vss to Vcc
CS# ≥ Vcc-0.2V
V
OH
2.4 - - V I
OH
= -1mA
Output high voltage
V
OH2
Vcc
- 0.5
- - V I
OH
= -0.1mA
Output low voltage
V
OL
- - 0.4 V I
OL
= 2mA
Note 1. Typical parameter indicates the value for the center of distribution at 5.0V (Ta= 25ºC), and not 100% tested.