Section 3 Software Specifications when Using the SH7080 Series/SH7146 Series/SH/Tiny Series
Rev. 5.00 Aug. 18, 2009 Page 51 of 78
REJ10J1237-0500
Figure 3.5 [Window trace] Page
Note: When [L-Bus] or [I-Bus] is selected, the following bus cycles will be traced.
L-Bus: A bus cycle generated by the CPU is acquired.
I-Bus: A bus cycle generated by the CPU, DMA, or DTC is acquired. (Some MCUs
will incorporate no DMAC or DTC.)