Technical information
23
MITSUBISHI MICROCOMPUTERS
3806 Group
SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER
Serial I/O2
The serial I/O2 function can be used only for clock synchronous
serial I/O.
For clock synchronous serial I/O the transmitter and the receiver
must use the same clock. If the internal clock is used, transfer is
started by a write signal to the serial I/O2 register.
Serial I/O2 control register (SIO2CON) 001D16
The serial I/O2 control register contains seven bits which control
various serial I/O functions.
Fig. 15 Structure of serial I/O2 control register
Fig. 16 Block diagram of serial I/O2 function
Serial I/O2 control register
(SIO2CON : address 001D
16
)
b7
Internal synchronous clock selection bits
0 0 0: f(X
IN
)/8
0 0 1: f(X
IN
)/16
0 1 0: f(X
IN
)/32
0 1 1: f(X
IN
)/64
1 1 0: f(X
IN
)/128
1 1 1: f(X
IN
)/256
Serial I/O2 port selection bit
0: I/O port
1: S
OUT2
,S
CLK2
signal output
S
RDY2
output enable bit
0: I/O port
1: S
RDY2
signal output
Transfer direction selection bit
0: LSB first
1: MSB first
Serial I/O2 synchronous clock selection bit
0: External clock
1: Internal clock
Not used (returns “0” when read)
b0
b2 b1 b0
X
IN
"1"
"0"
"0"
"1"
"0"
"1"
SRDY2
SCLK2
"0"
"1"
1/8
1/16
1/32
1/64
1/128
1/256
Data bus
Serial I/O2
interrupt request
Serial I/O2 port selection bit
Serial I/O counter 2 (3)
Serial I/O shift register 2 (8)
Synchronization circuit
Serial I/O2 port selection bit
Serial I/O2 synchronous
clock selection bit
S
RDY2 output enable bit
External clock
Internal synchronous
clock selection bits
Divider
P73 latch
P7
3
/S
RDY2
P7
2
/S
CLK2
P7
1
/S
OUT2
P7
0
/S
IN2
P72 latch
P7