User`s manual
5 Setup the Debugger
5.1.3 Emulator Tab
5.1.3.1 Specify the Target Clock
Change the setting by synchronizing with the clock used by the target microcomputer. (Internal is set
by default.)
Select Internal to set the internal clock, and External to set the external clock.
The specified content becomes effective when the next being start.
In addition to Internal and External, the main clock can be chosen to be a clock which is internally
generated in the emulator according to a specified clock frequency (user-defined clock).
To use a user-defined clock, select Generated and enter the clock frequency used in the Generated
frequency input area.
• The Generated frequency value can be entered in the range of 1.0 MHz to 99.9 MHz in 0.1 MHz
increments.*
• The Generated frequency value can only be set or changed when you start the debugger.
• Unless any value is set in the Generated frequency input area, the option "Generated" cannot be
selected.