REJ10J1495-0100
The zone time measurement error shown below is generated when Branch, Data or Trigger is
specified for the event setup function -- one of the zone time measurement functions. If Chip Event is
specified for the event setup function, no measurement error occurs.
" Time measurement error (clock count required to output a unit of information x 2)
M32100T2-SDI-E
Emulator model, Patterns of connection
M32100T-SDI-E
or
M32170T-SDI
When
M32xxxT2-PTC
is not used
When
M32xxxT2-PTC
is used
MCU
group
MCU operation
frequency
A unit of
information
outputted -
(a) Branch
information
(b) Data access
information
Number of time
measurement
error clocks
Number of time
measurement
error clocks
Number of time
measurement
error clocks
(a) 24 32102 -
(b) 36
(a) 24 M32Rx/D -
(b) 36
(a) 12 32121 -
(b) 18
(a) 12 3217x -
(b) 18
(a) 12 MCU clock
<= 66MHz
(b) 18
(a) 24 12
3218x
MCU clock
> 66MHz
(b) 36 18
(a) 12 MCU clock
<= 66MHz
(b) 18
(a) 24 12 66MHz <
MCU clock
<= 108MHz
(b) 36 18
(a) 24 108MHz <
MCU clock
<= 132MHz
(b) 36
(a) 48 24
32104
MCU clock
> 132MHz
(b) 72 36
(a) 12 (max) MCU clock
<= 66MHz
(b) 18 (max)
(a) 24 (max) 12 (max) 66MHz <
MCU clock
<= 108MHz
(b) 36 (max) 18 (max)
(a) 24 (max) 108MHz <
MCU clock
<= 132MHz
(b) 36 (max)
(a) 48 (max) 24 (max)
3219x
MCU clock
> 132MHz
(b)
72 (max) 36 (max)