User`s manual

M3T-PD32R V.5.01 Release 00 Release Notes
Rev.1.00 10.01.2006 page 29 of 34
REJ10J1495-0100
7.8. PD32R V.2.00 Release 1
7.8.1. Revisions of Restrictions
" A limitation has been corrected: If any structure whose member names exceed 1,024 characters in
total is displayed on the C Watch, Global, File Local, or Local window, the debugger may be forcibly
terminated.
(for detail, refer the MESC TOOL NEWS, October 16, 2000 (MESCT-PD32RSIM-001016D))
7.8.2. Extended Function
" Window-related Functions
GUI Input Window
GUI Input Window has been added. You can make a virtual key input panel on this window. This
window works as virtual input port.
GUI Output Window
GUI Output Window has been added. You can make a virtual output panel on this window.
Call Stack Window
Call Stack Window has been added. This window displays function call information of C language.
Dump Window, RAM Monitor Window and Memory Window
You can specify display start address, when you open a Dump Window, RAM Monitor
Window or Memory Window.
The display start address of the Dump Window, RAM Monitor Window or Memory Window is
displayed on the title bar.
ASM watch window
It has been made possible to specify a data length when registering watch points by bit
specification.
C Watch Window and ASM Watch Window
You can specify where C and ASM watch point file is saved.
You can save C and ASM watch points by each project.
Script Window
Command history can be saved. When you type up-arrow or down-arrow key on the input
field in focus, commands in the history can appear in order.
RELOAD command has been added. This command reloads your last target program.
PD Window
You can switch the display of the toolbar on or off.
PC Break Window
A PC break window has been added, from which pre-execution PC or post-execution PC
breakpoints can be set and inspected.
Hardware breakpoint setup dialog box, trace point setup dialog box, state transition break
window, state transition trace window, and time measurement window
It has been made possible to set a data information output address range during data trace.
" Others
Customizing User Interfaces
Shortcut key assignment and toolbar customizing functions have been added.
Shortcut menu
Right click on each window displays its own option menu as a shortcut.
Supplemental Download Function for Binary Data
After downloading an absolute module file, you can download supplemental binary data (MOT
files) with keeping symbol debugging information.
Saving window information and Resuming
Size, location and the other information of each window resume at opening each window. This