User`s manual
M3T-PD32R V.5.01 Release 00 Release Notes
Rev.1.00 10.01.2006 page 29 of 34
REJ10J1495-0100
7.8. PD32R V.2.00 Release 1
7.8.1. Revisions of Restrictions
" A limitation has been corrected: If any structure whose member names exceed 1,024 characters in
total is displayed on the C Watch, Global, File Local, or Local window, the debugger may be forcibly
terminated.
(for detail, refer the MESC TOOL NEWS, October 16, 2000 (MESCT-PD32RSIM-001016D))
7.8.2. Extended Function
" Window-related Functions
− GUI Input Window
GUI Input Window has been added. You can make a virtual key input panel on this window. This
window works as virtual input port.
− GUI Output Window
GUI Output Window has been added. You can make a virtual output panel on this window.
− Call Stack Window
Call Stack Window has been added. This window displays function call information of C language.
− Dump Window, RAM Monitor Window and Memory Window
•
•
•
•
•
•
•
•
•
•
You can specify display start address, when you open a Dump Window, RAM Monitor
Window or Memory Window.
The display start address of the Dump Window, RAM Monitor Window or Memory Window is
displayed on the title bar.
− ASM watch window
It has been made possible to specify a data length when registering watch points by bit
specification.
− C Watch Window and ASM Watch Window
You can specify where C and ASM watch point file is saved.
You can save C and ASM watch points by each project.
− Script Window
Command history can be saved. When you type up-arrow or down-arrow key on the input
field in focus, commands in the history can appear in order.
RELOAD command has been added. This command reloads your last target program.
− PD Window
You can switch the display of the toolbar on or off.
− PC Break Window
A PC break window has been added, from which pre-execution PC or post-execution PC
breakpoints can be set and inspected.
− Hardware breakpoint setup dialog box, trace point setup dialog box, state transition break
window, state transition trace window, and time measurement window
It has been made possible to set a data information output address range during data trace.
" Others
−
Customizing User Interfaces
Shortcut key assignment and toolbar customizing functions have been added.
− Shortcut menu
Right click on each window displays its own option menu as a shortcut.
− Supplemental Download Function for Binary Data
After downloading an absolute module file, you can download supplemental binary data (MOT
files) with keeping symbol debugging information.
− Saving window information and Resuming
Size, location and the other information of each window resume at opening each window. This