User`s manual

M3T-PD32R V.5.01 Release 00 Release Notes
Rev.1.00 10.01.2006 page 23 of 34
REJ10J1495-0100
6.3. Security code check function
When starting PD32R in which a security code is stored, the following dialog appears. Enter the
security code here. If the entered security code does not match the stored one, PD32R will not get
started until the data in the built-in flash memory is deleted.
Enter the security code in the edit box.
Select the security code format by using a radio button in the Format group.
When checking the Save check box, the entered security code is saved.
When you try to start PD32R at next time, the system uses the saved security code to verify
conformance to the stored security code.
6.4. Setting a breakpoint in the Program/Source Window
When you try to set a breakpoint in the Program/Source Window at an write-protected area, a
pre-execution PC breakpoint is set.
6.5. Display value of breakpoint display/setting area in the Program/Source Window
In the breakpoint display/setting area in the Program/Source Window, "b" is displayed when a
pre-execution PC breakpoint has been set, and "p" is displayed when a post-execution PC breakpoint
has been set.
If a software breakpoint, hardware breakpoint (instruction branch), a pre-execution PC breakpoint
and a post-execution PC breakpoint are set at the same address, "ALL" is displayed in the
breakpoint display/setting area in the Program/Source Window.