Datasheet

M32C/8A Group 5. Electrical Characteristics
REJ03B0213-0111 Rev.1.11 Mar 31, 2009
Page 45 of 66
Timing Requirements
(VCC1 = VCC2 = 4.2 to 5.5 V, VSS = 0 V, Topr = -20 to 85°C unless otherwise specified)
Table 5.25 Microprocessor Mode
NOTE:
1. Values, which depend on BCLK frequency and external bus cycles, can be obtained from the following
equations. Insert wait states or lower the operation frequency, f(BCLK), if the calculated value is negative.
10
9
× m
f(BCLK) × 2
- 35 [ns] (if external bus cycle is aφ + bφ, m = (b × 2) + 1)
tac1(RD-DB) =
10
9
× n
f(BCLK)
- 35 [ns] (if external bus cycle is aφ + bφ, n = a + b)
tac1(AD-DB) =
10
9
× m
f(BCLK) × 2
- 35 [ns] (if external bus cycle is aφ + bφ, m = (b × 2) - 1)
tac2(RD-DB) =
10
9
× p
f(BCLK) × 2
- 35 [ns] (if external bus cycle is aφ + bφ, p = {(a + b - 1) × 2} + 1)
tac2(AD-DB) =
Symbol Parameter
Standard
Unit
Min. Max.
tac1(RD-DB)
Data input access time (RD standard) (note 1)
ns
tac1(AD-DB)
Data input access time (AD standard, CS standard) (note 1)
ns
tac2(RD-DB)
Data input access time (RD standard, when accessing a space with the
multiplexed bus)
(note 1)
ns
tac2(AD-DB)
Data input access time (AD standard, when accessing a space with the
multiplexed bus)
(note 1)
ns
tsu(DB-BCLK)
Data input setup time 26
ns
tsu(RDY-BCLK)
RDY input setup time
26
ns
tsu(HOLD-BCLK)
HOLD input setup time
30
ns
th(RD-DB)
Data input hold time 0
ns
th(BCLK-RDY)
RDY input hold time
0
ns
th(BCLK-HOLD)
HOLD input hold time
0
ns
td(BCLK-HLDA)
HLDA output delay time
25
ns
VCC1 = VCC2 = 5V