User`s manual

Chapter 3. Setup
( 41 / 74 )
3.6.2 Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 2)
Here following is a procedure of connecting to a 100-pin 0.5-mm-pitch foot pattern on the user system using the
M3T-100LCC-QSD (not included). For details on the M3T-100LCC-QSD, refer to its user's manual.
(1) Attach the M3T-100LCC-QSD to the user system.
(2) Attach the CN2 side of the M30800T-PTC to the J4 side of the M306NKT-EPB.
(3) Attach the M30800T-PTC to the M3T-100LCC-QSD.
Figure 3.17 Connecting to a 100-pin 0.5-mm-pitch foot pattern (Part 2)
CAUTION
Notes on Connecting the User System:
z Take care not to attach a converter board in a wrong direction. It may cause a fatal damage to the
emulator and targets system.
z The connectors of the M30800T-PTC and M3T-100LCC-QSD are guaranteed for only 50
insertion/removal iterations.
M3T-100LCC-QSD
(not included)
CN2 side
(4)
(5)
M30800T-PTC
(3)
(2)
TQSOCKET100SDG
TQPACK100SD
(1)
100-pin 0.5-mm-pitch
(100P6Q-A)
foot pattern
No. 1 pin
User target
M3T-FLX160-EPB
M306NKT-EPB