Datasheet
20. Flash Memory Version
puorG92/C61M
page 353
854fo7002,03.raM21.1.veR
2110-1010B90JER
Figure 20.14 Full Status Check and Handling Procedure for Each Error
Full status check
FMR06 =1
and 
FMR07=1?
NO
Command 
sequence error
YES
FMR07=
0?
YES
Erase error
NO
(1) Execute the clear status register command and set 
the status flag to 0 whether the command is 
entered.  
(2) Execute the command again after checking that the 
correct command is entered or the program 
command or the block erase command is not 
executed on the protected blocks.
(1) Execute the clear status register command and set 
the erase status flag to 0.
(2) Execute the block erase command again.
(3) Execute (1) and (2) at least 3 times until an erase 
error does not occur.  
Note 3: If bits FMR06 or FMR07 is 1, any of the program or block erase command cannot be 
accepted. Execute the clear status register command before executing those commands.
FMR06=
0?
YES
Program error
NO
Full status check completed
Note 1: If the error still occurs, the block can not be 
used.
(1) Execute the clear status register command and set 
the program status flag to 0.
(2) Execute the program command again.
Note 2: If the error still occurs, the block can not be 
used.
[During programming]