Datasheet

Table Of Contents
17. Flash Memory Version
page 253
923fo7002,51.beF00.2.veR
0020-2020B90JER
)T62/C61M,B62/C61M,A62/C61M(puorGA62/C61M
Full status check
FMR06 =1
and
FMR07=1?
NO
Command
sequence error
YES
FMR07=0?
YES
Erase error
NO
(1) Execute the clear status register command and set
the status flag to 0 whether the command is
entered.
(2) Reexecute the command after checking that it is
entered correctly or the program command or the
block erase command is not executed for the
blocks which are protected.
(1) Execute the clear status register command and set
the erase status flag to 0.
(2) Reexecute the block erase command.
(3) Execute (1) and (2) at least 3 times until an erase
error is not generated.
Note 3: If the FMR06 or FMR07 bits is 1, any of the Program or Block Erase command can not
be aknowledged. Execute the clear status register command before executing those
commands.
FMR06=0?
YES
Program error
NO
Full status check completed
Note 1: If the error still occurs, the block can not be
used.
(1) Execute the clear status register command and set
the program status flag to 0.
(2) Reexecute the Program command.
Note 2: If the error still occurs, the block can not be
used.
[During programming]
Figure 17.8.4.1. Full Status Check and Handling Procedure for Each Error