Datasheet

Table Of Contents
12. Timer
page 128
923fo7002,51.beF00.2.veR
0020-2020B90JER
)T62/C61M,B62/C61M,A62/C61M(puorGA62/C61M
12.3.1 Position-data-retain Function
This function is used to retain the position data synchronously with the three-phase waveform
output.There are three position-data input pins for U, V, and W phases.
A trigger to retain the position data (hereafter, this trigger is referred to as "retain trigger") can be selected
by the retain-trigger polarity select bit(bit 3 of the position-data-retain function control register, at address
034E16). This bit selects the retain trigger to be the falling edge of each positive phase, or the rising edge
of each positive phase.
12.3.1.1 Operation of the Position-data-retain Function
Figure 12.3.1.1.1 shows a usage example of the position-data-retain function (U phase) when the
retain trigger is selected as the falling edge of the positive signal.
(1) At the falling edge of the U-phase waveform ouput, the state at pin IDU is transferred to the U-
phase position data retain bit ( bit2 at address 034E16 ).
(2) Until the next falling edge of the Uphase waveform output,the above value is retained.
Figure 12.3.1.1.1 Usage Example of Position-data-retain Function ( U phase )
T
r
a
n
sfe
rr
ed
Carrier wave
U-phase waveform output
U-phase waveform output
1 2
T
r
a
n
sfe
rr
ed
T
r
a
n
sfe
rr
ed
T
r
a
n
sfe
rr
ed
Pin IDU
NOTE:
1. The retain trigger is the falling edge of the positive signal.
PDRU bit in the RDRF register