User`s manual
11
2.2.3 Precautions on Connecting the User System
When connecting the emulator to the user system, note the following:
1. Secure the E6000H station location.
Place the E6000H station and the E6000H’s front-end unit so that the trace cable is not bent or twisted, as
shown below. A bent or twisted cable will impose stress on the user interface, leading to connection or
contact failure. Make sure that the E6000H station and the front-end unit are placed in a secure position so
that they do not move and impose stress on the user interface while being used.
RENESAS
E6000H
RENESAS
E6000H
RENESAS
E6000H
OK
NG
NG
2. Make sure the power supply is off.
Before connecting the emulator to the user system, check that the emulator and the user system are turned off.
3. Connect Vcc to the user system power.
The emulator monitors and determines whether the user system is turned on or off by the Vcc pins.
After connecting the user system to the emulator via the user system interface cable, be sure to supply power
to the Vcc pins. Otherwise, the emulator assumes that the user system is not connected.
When the user system is connected, check that the power of the user system is supplied to these pins.