User`s manual
53
[Clock/8]: Time stamping is in terms of the number of bus-clock cycles, i.e., is
synchronized with 1/8 cycle of the system clock signal (φ).
[Selection of the trace contents]:
Selects whether or not to display time stamps, IRQs, or executed instructions.
[Detailed time stamp]: Acquires 32-bit time stamp information. No IRQ or executed instruction is
displayed.
[Execute code,Irq]: Displays IRQs and executed instructions. Lower 16 bits of time stamps are
fixed to 0.