User`s manual
10
2.2 Emulator Connection
The following description covers connection of the emulator.
2.2.1 Connecting the Emulator to the User System
WARNING
Always switch OFF the emulator and user system before
connecting or disconnecting any CABLES. Failure to do so will result
in a FIRE HAZARD and will damage the user system and the emulator
or will result in PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Check that the emulator power switch is turned off. Ensure that the power lamp on the right side of the
E6000H station's front panel is not lit.
2. Remove the AC power cable of the E6000H station from the outlet (if the cable is connected to the outlet).
3. The emulator is connected to the user system via the user system interface cable.
2.2.2 Connecting the User System Interface Cable
WARNING
Always switch OFF the emulator and user system and check
pin numbers on the connectors and IC socket before connecting
or disconnecting the USER SYSTEM INTERFACE CABLE.
Connection with the power on or incorrect connection will damage
the emulator, user system interface cable, and user system, and
result in a FIRE HAZARD.
For details on the method of connecting the user system interface cable, refer to the descriptions of the user
system interface cables for individual H8SX/1544 E6000H-series products.