5
1.2.2 Front-end Unit Configuration
The names of the components on the front-end unit are listed below.
18
12. 5
5. 5
43. 6
12430. 6
162. 8
PCN2
UCN1
XTAL
(a)
(b)
(c)
(d)
HS1544EPH60H
Unit:mm
Tolerance:
0.2mm
Figure 1.4 Configuration and Dimensions of the Emulator’s Front-end Unit
(a) Crystal oscillator terminals: For installing a crystal oscillator to be used as
an external clock source for the MCU.
(b) External probe connector: For connecting the external probe for external signal tracing and
multibreak detection.
(c) User system interface cable For connecting the user system interface cable.
connector: