User`s manual
34
4.3 Diagnostic Test Procedure Using the Diagnostic Program
Insert the CD-R (HS1650EPH60SR supplied with the emulator) into the CD-ROM drive of the host computer,
use the command prompt to change the current directory to <Drive>:\Diag\1527, and enter the command below
that corresponds to the PC interface board used to initiate the diagnostic program:
1. PCI bus interface board (HS6000EIC01H or HS6000EIC02H)
> TM1527
–PCI (Enter)
2. PC card interface (HS6000EIP01H)
> TM1527
–PCCD (Enter)
3. LAN adapter (HS6000ELN01H)
> TM1527
–ELN (Enter)
4. USB adapter (HS6000EIU01H or HS6000EIU02H)
> TM1527
–USB (Enter)
The High-performance Embedded Workshop must be installed before the test program is executed.
Be sure to initiate the diagnostic program from <Drive>:\Diag\1527. Do not initiate it from a directory other
than <Drive>:\Diag\1527, such as > <Drive>:\Diag\1527\TM1527
–PCI (Enter). If the diagnostic program is
initiated when the current directory is not <Drive>:\Diag\1527, the diagnostic program will not operate correctly.
When
–S is added to the command line, as in > TM1527 –PCI –S (Enter), steps 1 to 15 will be repeatedly
executed. To stop execution in this case, enter Q.
Notes: 1. <Drive> is the drive name of the CD-ROM drive.
2. Do not remove the CD-R from the CD-ROM drive during execution of the test program.