26.3.5 Multifunction Timer Pulse Unit Timing
Table 26.9 Multifunction Timer Pulse Unit Timing (Conditions:V
CC
= 3.0
*
to 3.6V, AV
CC
=
3.0
*
to 3.6V, AV
CC
= V
CC
± 10%, AV
ref
= 3.0
*
to AV
CC
, V
SS
= AV
SS
= 0V, T
a
=
–20 to +75°C)
Item Symbol Min Max Unit Figure
Output compare output delay time t
TOCD
100 ns 26.23
Input capture input setup time t
TICS
100 ns
Timer input setup time t
TCKS
100 ns 26.24
Timer clock pulse width (single edge
specification)
t
TCKWH/L
1.5 t
cyc
Timer clock pulse width (both edges
specified)
t
TCKWH/L
2.5 t
cyc
Timer clock pulse width (phase
measurement mode)
t
TCKWH/L
2.5 t
cyc
Note: * SH7042/43 ZTAT (excluding A mask) are 3.2V.
CK
t
TOCD
t
TICS
Input
capture input
Output
compare output
Figure 26.23 MTU I/O Timing
CK
TCLKA
to TCLKD
t
TCKS
t
TCKS
t
TCKWH
t
TCKWL
Figure 26.24 MTU Clock Input Timing