Datasheet
384
Buffer Operation Timing: Compare-match buffer operation timing is shown in figure 12.67.
Figure 12.68 shows input capture buffer operation timing.
TCNT
φ
Compare-
match buffer
signal
TGRA, TGRB
TGRC, TGRD
n n + 1
nN
N
Compare-
match signal
Figure 12.67 Buffer Operation Timing (Compare-Match)
TCNT
φ
Input capture
signal buffer
TGRA, TGRB
TGRC, TGRD
N N + 1
nN
n
N + 1
N
Input capture
signal
Figure 12.68 Buffer Operation Timing (Input Capture)