Datasheet

383
Counter Clearing Timing Due to Compare-Match/Input Capture: Timing for counter clearing
due to compare-match is shown in figure 12.65. Figure 12.66 shows the timing for counter
clearing due to input capture.
Compare-
match signal
φ
Counter
clear signal
TCNT
TGR
N
N
H'0000
Figure 12.65 Counter Clearing Timing (Compare-Match)
Input
capture
signal
φ
Counter
clear signal
TCNT
TGR
N
N
H'0000