Datasheet
Section 16 Serial Communication Interface 3 (SCI3) 
Rev.5.00 Nov. 02, 2005 Page 282 of 500 
REJ09B0027-0500   
Yes
<End>
No
Start reception
[1]
No
Yes
Read RDRF flag in SSR
[2]
[3]
Clear RE bit in SCR3 to 0
Read OER, PER, and
FER flags in SSR
Error processing
(Continued on next page)
[4]
Read receive data in RDR
Yes
No
OER+PER+FER = 1
RDRF = 1
All data received?
[1]  Read the OER, PER, and FER flags in 
SSR to identify the error. If a receive 
error occurs, performs the appropriate 
error processing. 
[2]  Read SSR and check that RDRF = 1, 
then read the receive data in RDR. 
The RDRF flag is cleared automatically.
[3]  To continue serial reception, before the 
stop bit for the current frame is 
received, read the RDRF flag and read 
RDR. 
 The RDRF flag is cleared automatically. 
[4]  If a receive error occurs, read the OER, 
PER, and FER flags in SSR to identify 
the error. After performing the 
appropriate error processing, ensure 
that the OER, PER, and FER flags are 
all cleared to 0. Reception cannot be 
resumed if any of these flags are set to 
1. In the case of a framing error, a 
break can be detected by reading the 
value of the input port corresponding to 
the RxD pin.
(A)
Figure 16.8 Sample Serial Reception Data Flowchart (Asynchronous Mode) (1) 