Datasheet
Section 13 Timer Z 
    Rev.5.00 Nov. 02, 2005 Page 201 of 500 
   REJ09B0027-0500 
H'0000
Time
Counter cleared by GR compare match
STR 
GR value 
TCNT value 
IMF
Figure 13.9 Periodic Counter Operation 
2.  TCNT count timing 
A. Internal clock operation 
A system clock (φ) or three types of clocks (φ/2, φ/4, or φ/8) that divides the system clock 
can be selected by bits TPSC2 to TPSC0 in TCR. 
Figure 13.10 illustrates this timing. 
TCNT
TCNT input
Internal clock
N-1 N N+1
φ
Figure 13.10 Count Timing at Internal Clock Operation 