Datasheet

Section 13 Serial Communication Interface 3 (SCI3)
Rev.4.00 Nov. 02, 2005 Page 194 of 304
REJ09B0143-0400
Transmitting
station
Receiving
station A
Receiving
station B
Receiving
station C
Receiving
station D
(ID = 01) (ID = 02) (ID = 03) (ID = 04)
Serial transmission line
Serial
data
ID transmission cycle =
receiving station
specification
Data transmission cycle =
Data transmission to
receiving station specified by ID
(MPB = 1) (MPB = 0)
H'01
H'AA
[Legend]
MPB: Multiprocessor bit
Figure 13.15 Example of Communication Using Multiprocessor Format