Datasheet
Section 13 Serial Communication Interface 3 (SCI3)
Rev.4.00 Nov. 02, 2005 Page 188 of 304
REJ09B0143-0400
No
<End>
Yes
Start transmission
Read TDRE flag in SSR[1]
Write transmit data to TDR
No
Yes
No
Yes
Read TEND flag in SSR
[2]
Clear TE bit in SCR3 to 0
TDRE = 1
All data transmitted?
TEND = 1
[1] Read SSR and check that the TDRE flag is
set to 1, then write transmit data to TDR.
When data is written to TDR, the TDRE flag
is automatically cleared to 0 and clocks are
output to start the data transmission.
[2] To continue serial transmission, be sure to
read 1 from the TDRE flag to confirm that
writing is possible, then write data to TDR.
When data is written to TDR, the TDRE flag
is automatically cleared to 0.
Figure 13.11 Sample Serial Transmission Flowchart (Clocked Synchronous Mode)