Datasheet
Section 13 Serial Communication Interface 3 (SCI3)
Rev.4.00 Nov. 02, 2005 Page 171 of 304
REJ09B0143-0400
Bit Bit Name Initial Value R/W Description
4 FER 0 R/W Framing Error
[Setting condition]
• When a framing error occurs in reception
[Clearing condition]
• When 0 is written to FER after reading FER = 1
3 PER 0 R/W Parity Error
[Setting condition]
• When a parity error is generated during
reception
[Clearing condition]
• When 0 is written to PER after reading PER = 1
2 TEND 1 R Transmit End
[Setting conditions]
• When the TE bit in SCR3 is 0
• When TDRE = 1 at transmission of the last bit of
a 1-byte serial transmit character
[Clearing conditions]
• When 0 is written to TEND after reading TEND
= 1
• When the transmit data is written to TDR
1 MPBR 0 R Multiprocessor Bit Receive
MPBR stores the multiprocessor bit in the receive
character data. When the RE bit in SCR3 is cleared
to 0, its previous state is retained.
0 MPBT 0 R/W Multiprocessor Bit Transfer
MPBT stores the multiprocessor bit to be added to
the transmit character data.