Datasheet

Section 6 Power-Down Modes
Rev. 6.00 Mar. 24, 2006 Page 86 of 412
REJ09B0142-0600
6.1.2 System Control Register 2 (SYSCR2)
SYSCR2 controls the power-down modes, as well as SYSCR1.
Bit Bit Name
Initial
Value R/W Description
7
6
5
SMSEL
LSON
DTON
0
0
0
R/W
R/W
R/W
Sleep Mode Selection
Low Speed on Flag
Direct Transfer on Flag
These bits select the mode to transit after the execution
of a SLEEP instruction, as well as bit SSBY of
SYSCR1.
For details, see table 6.2.
4
3
2
MA2
MA1
MA0
0
0
0
R/W
R/W
R/W
Active Mode Clock Select 2 to 0
These bits select the operating clock frequency in
active and sleep modes. The operating clock frequency
changes to the set frequency after the SLEEP
instruction is executed.
0XX: φ
OSC
100: φ
OSC
/8
101: φ
OSC
/16
110: φ
OSC
/32
111: φ
OSC
/64
1
0
SA1
SA0
0
0
R/W
R/W
Subactive Mode Clock Select 1 and 0
These bits select the operating clock frequency in
subactive and subsleep modes. The operating clock
frequency changes to the set frequency after the
SLEEP instruction is executed.
00: φ
W
/8
01: φ
W
/4
1X: φ
W
/2
[Legend]
X: Don't care.