REJ10J1396-0300 H8SX/1582 PLQP0120LA-A User System Interface Cable HS1582ECH61H User’s Manual Renesas Microcomputer Development Environment System H8SX Family / H8SX/1500 Series HS1582ECH61HE Rev.3.00 Revision Date: Sep.
Rev. 3.00 Sep.
Notes regarding these materials 1. This document is provided for reference purposes only so that Renesas customers may select the appropriate Renesas products for their use. Renesas neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any other rights of Renesas or any third party with respect to the information in this document. 2.
Rev. 3.00 Sep.
IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User System Interface Cable: Throughout this document, the term "user system interface cable" shall be defined as the following product produced only by Renesas Technology Corp. excluding all subsidiary products.
LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will repair or replace any user system interface cables determined to be defective in material and/or workmanship. User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use.
State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state.
SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance. 2. Always switch OFF the E6000H emulator and user system before connecting or disconnecting any CABLES or PARTS. 3.
Rev. 3.00 Sep.
Preface The HS1582ECH61H is a user system interface cable that connects an H8SX/1582 E6000H emulator (HS1527KEPH60H; hereinafter referred to as the emulator) to the IC socket for an PLQP0120LA-A (former package: FP-120B) package for the H8SX/1582 MCU on the user system.
Contents Section 1 Configuration...........................................................................................1 Section 2 Connection Procedures ............................................................................3 2.1 2.2 2.3 2.4 2.5 Connecting User System Interface Cable to Emulator Station ............................................. 3 Connecting User System Interface Cable to User System .................................................... 5 2.2.1 Installing IC Socket.............
Section 1 Configuration Section 1 Configuration CAUTION Use an NQPACK120SE-ND socket and an HQPACK120SE cover (manufactured by Tokyo Eletech Corporation) for the PLQP0120LA-A package IC socket on the user system. Figure 1 and table 1 show the external appearance and components, respectively, of the HS1582ECH61H user system interface cable for the PLQP0120LA-A package. To emulator station Cable body Screws (M2.0 x 10 mm) (for fastening cable head) Screws (M2.
Section 1 Configuration Table 1 lists the HS1582ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1582ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the PLQP0120LA-A package 4 Socket cover 1 For installing an PLQP0120LA-A packaged MCU 5 Screws (M2.0 x 10 mm) 4 For fastening cable head 6 Screws (M2.
Section 2 Connection Procedures Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part.
Section 2 Connection Procedures 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket (figure 2). E6000H RENESAS HS1527KEPH60H emulator station Cable body connector User system interface cable Figure 2 Example of the HS1527KEPH60H Emulator Station Rev. 3.00 Sep.
Section 2 Connection Procedures 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST.
Section 2 Connection Procedures Use the guide pins provided to determine where to install the IC socket, as shown in figure 3. Pin 1 Guide pins 4 projections to apply epoxy resin adhesive to IC socket (NQPACK120SE-ND manufactured by Tokyo Eletech Corporation) Bottom view of IC socket User system Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for an PLQP0120LA-A package to the user system.
Section 2 Connection Procedures 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an PLQP0120LA-A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4. 2.2.4 Fastening Cable Head CAUTION 1. Use a screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N•m or less.
Section 2 Connection Procedures Fasten the user system interface cable head to the IC socket for an PLQP0120LA-A package on the user system with the four screws (M2.0 x 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2.
Section 2 Connection Procedures 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the unfastening jig Unfastening jig Cable head User system Figure 5 Fastening Cable Body Rev. 3.00 Sep.
Section 2 Connection Procedures 2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an PLQP0120LA-A package (NQPACK120SE-ND: manufactured by Tokyo Eletech Corporation). The dimensions in figure 6 are somewhat different from those of the actual chip's mount pad. Also, note the user system can not be connected to the user system interface cable with inserting the guide pins in place. 0.
Section 2 Connection Procedures 2.4 Dimensions for User System Interface Cable Head 23.0 20.25 23.0 66.04 The dimensions for the user system interface cable head are shown in figure 7. 20.25 63.5 Unit: mm Tolerance: ±0.5 mm Figure 7 Dimensions for User System Interface Cable Head Rev. 3.00 Sep.
Section 2 Connection Procedures 2.5 Resulting Dimensions after Connecting User System Interface Cable 21.5 The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. 13.3 Cable head User system IC socket (NQPACK120SE-ND manufactured by Tokyo Eletech Corporation) Unit: mm Tolerance: ±0.5 mm Figure 8 Resulting Dimensions after Connecting User System Interface Cable Rev. 3.00 Sep.
Section 3 Installing the MCU to the User System Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a screwdriver whose head matches the screw head. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Section 3 Installing the MCU to the User System Screws (M2.0 x 6 mm) Socket cover (HQPACK120SE manufactured by Tokyo Eletech Corporation) MCU Pin 1 IC socket (NQPACK120SE-ND manufactured by Tokyo Eletech Corporation) User system Figure 9 Installing MCU to User System Rev. 3.00 Sep.
Section 4 Verifying Operation Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). 2. Verify the user system interface cable connections by checking the pin states with the CHECK command (emulator command). If an error is detected, recheck the soldered IC socket and the location of pin 1. 3.
Section 4 Verifying Operation Rev. 3.00 Sep.
Section 5 Notice Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. This user system interface cable is specifically designed for the HS1527KEPH60H emulator. Do not use this cable with any other emulator station. 3. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable. 4.
Section 5 Notice P4 short connector. For details on the differences between the target MCU and the emulator, refer to the H8SX/1650 E6000H Emulator User's Manual (HS1650EPH60HE). For the ranges of input voltages of AVcc0 and AVcc1, refer to the H8SX/1520 Group Hardware Manual. CAUTION Insert the jumper pin in the P4 short connector so that the higher voltage between AVcc0 and AVcc1 is selected. Select either AVcc0 or AVcc1 when their potentials are the same. Do not use the emulator without jumper pins.
H8SX/1582 PLQP0120LA-A User System Interface Cable HS1582ECH61H User's Manual Publication Date: Rev.1.00, June 15, 2004 Rev.3.00, September 8, 2008 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Customer Support Department Global Strategic Communication Div. Renesas Solutions Corp. © 2008. Renesas Technology Corp., All rights reserved. Printed in Japan.
Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan RENESAS SALES OFFICES http://www.renesas.com Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
H8SX/1582 PLQP0120LA-A User System Interface Cable HS1582ECH61H User’s Manual