User`s manual

182
[General] page (cont)
[Break on access error] When this box is checked, a break (the user program stops) occurs if
your program accesses an access-prohibited area or writes to a write-
protected area.
[Enable internal ROM area write] When this box is checked, writing to the internal ROM area is enabled.
For the result of writing, see the [Status] window.
[User VCC Threshold] Sets the voltage level for the user system. [Down] will be displayed in
[User System Voltage] of the [Extended Monitor] window when the actual
user VCC of the target system is lower than the specified value.
[User Signals] When this box is checked, the reset, NMI, and bus request signals from
the user system are enabled. Note that the standby signal is always
invalid because the hardware standby function is not supported.
However, the status of the signal can be checked in the [Extended
Monitor] window.
[Driver] Displays the E6000 driver that is currently installed.
[Change driver in start up] When this box is checked, selection of a driver will be available next time
the emulator is connected.
The MCUs selectable by the [Device] option and options that depend on the MCUs are listed below. To emulate
an MCU with a description in the Expansion Hardware column, connect the correct expansion hardware.