Technical information
6 / 7
1.16.4 Synchronization with the [Monitor] window
Do not enable the automatic update of float- and double-type variables. The values of float- and
double-type variables will not be correctly displayed if they are automatically updated during execution of
the user program. If you want to check the values, use the monitoring function ([Monitor] window).
1.17 Command Line Interface
• Specifying a File
If a file is specified in the relative path format for a command line parameter, an access to the file may not
be available. A file must be specified in the absolute path format when using a command line.
• Batch File
If the message “Not currently available” is displayed while executing a batch file, enter the sleep
command. Adjust the length of sleep time since it varies according to the operating environment.
Example: When “Not currently available” is displayed during memory_fill execution:
sleep d’3000
memory_fill 0 ffff 0
• Overwrite File
In Command Line Interface, a file that has the same name as the output file is overwritten without asking
the user.
• Log File
To change the target platform due to a change of the session while logging of the command line window,
halt logging.
• GO_TILL Command
If the GO_TILL command executed by specifying “wait” as the parameter is terminated with an error, the
command processing may not be available. In such cases, select [Stop] in the popup menu of the
command line window to perform the command processing.
1.18 Monitoring Function
1.18.1 Changing Monitor Settings during User Program Execution
If you change the monitor settings in the [Monitor] window during execution of the user program, the
initial values will be undefined.
1.19 Installation and Uninstallation
1.19.1 Uninstallation from [Tool Administration]
Note that a message dialog box appears for confirmation if the folder to be removed includes a file other
than those installed. Even though this dialog box is displayed, press the [Ignore] button to continue
uninstallation.
1.19.2 [Add/Remove Programs Properties] of the Control Panel
Note the followings:
• Uninstalling from [Add/Remove Programs Properties] of the control panel only removes folders and
files of the product most recently installed if several products that conform to High-performance
Embedded Workshop have been installed. Use the explorer to remove the folders and files of the rest
of the products.
• Once uninstallation is attempted, even products that were not removed may not operate correctly. If
you want to use these products, re-install them.
1.19.3 Usage with Other Products
To install the SuperH™ RISC engine C/C++ compiler package or H8S, H8/300 series C/C++ compiler
package after installing the E6000 emulator software for High-performance Embedded Workshop, select
[High-performance Embedded Workshop] as the component to be installed in [Select Components] during
installation of the compiler package.