Hardware manual
Microcomputer Technical Q&A
31
Q&A No.: QAH8S-027
Category: Interrupts
Subject: Interrupt Immediately after Reset
Question
Is an interrupt ever generated immediately after a reset?
Answer
No, never. Immediately after a reset, all interrupts, including NMI, are disabled. However, NMI is
accepted when the first instruction of the program is executed.
Applicable Products
Applicability Series Applicability Series Applicability Series
Yes Entire H8S Series H8S/2655 H8S/2350
H8S/2355 H8S/2357 H8S/2345
H8S/2245 H8S/2148 H8S/2144
H8S/2138 H8S/2134 H8S/2128
H8S/2124 — — — —