Hardware manual
Microcomputer Technical Q&A
96
Q&A No.: QAH8S-222
Category: TPU
Subject: Synchronous Operation of Two Sets
Question
Is synchronous operation of two sets possible?
Answer
No. The timer synchro register (TSYR) does not permit a synchronous operation setting for two or
more sets.
Applicable Products
Applicability Series Applicability Series Applicability Series
Entire H8S Series Yes H8S/2655 Yes H8S/2350
Yes H8S/2355 Yes H8S/2357 Yes H8S/2345
Yes H8S/2245 H8S/2148 H8S/2144
H8S/2138 H8S/2134 H8S/2128
H8S/2124 — — — —